You will be asked to void (urinate). The time it takes you to begin voiding, and the size, force, and continuity of your urinary stream will be recorded. The amount of urine, how long it took you to empty your bladder, and any straining, hesitancy, or dribbling that occurred are recorded. You lie down, and a thin, flexible tube (catheter) is gently positioned in your bladder to measure and record any urine left in the bladder. A catheter is then placed in your rectum, and measuring electrodes are placed near the rectum (perineum). Next, thermal sensation is measured. Room-temperature saline solution is placed into the bladder, followed by warm water. You will tell the health care provider what, if any, sensations you feel. The water is then drained from the bladder. A a tube used to monitor bladder pressure (cystometer) is then connected to the catheter. Water or carbon dioxide gas is slowly introduced into the bladder at a controlled rate. You will be asked to tell the provider when you first feel the need to urinate. When the bladder is full, you must urinate, and the pressure of this urination is recorded. The bladder is again drained of any urine or water, and the catheter is removed. |